/v1/motor-power
Hoist-motor power at full load
Try it live
10 free calls per day — no sign-up, no API key. Goes through the oanor gateway.
It works. Grab an API key and use it in your project.
Get an API keyCode snippets
curl "https://api.oanor.com/elevator-api/v1/motor-power" \ -H "x-oanor-key: oanor_test_..."
await fetch("https://api.oanor.com/elevator-api/v1/motor-power", {
headers: { "x-oanor-key": "oanor_test_..." }
});
$ch = curl_init("https://api.oanor.com/elevator-api/v1/motor-power");
curl_setopt($ch, CURLOPT_HTTPHEADER, ["x-oanor-key: oanor_test_..."]);
curl_setopt($ch, CURLOPT_RETURNTRANSFER, true);
$out = curl_exec($ch);
import requests
requests.get(
"https://api.oanor.com/elevator-api/v1/motor-power",
headers={"x-oanor-key": "oanor_test_..."}
)
Example response
A real response from this endpoint, captured by the latest health check.
{
"data": {
"note": "Because the counterweight cancels most of the car, the hoist motor only lifts the out-of-balance load = rated load × (1 − overbalance). Power = that mass × g × speed ÷ efficiency (~65–75 % for a geared machine, higher gearless). A 1,000 kg lift at 45 % overbalance and 1.5 m/s needs the motor to lift ~550 kg, about 11–12 kW — far less than the ~21 kW a hoist without a counterweight would need.",
"inputs": {
"speed_mps": 1.5,
"balance_pct": 45,
"rated_load_kg": 1000,
"efficiency_pct": 70
},
"motor_power_hp": 15.5,
"motor_power_kw": 11.56,
"out_of_balance_load_kg": 550
},
"meta": {
"timestamp": "2026-06-07T08:17:57.839Z",
"request_id": "c000e185-ef64-460c-bcfe-724e78f09aad"
},
"status": "ok",
"message": "Motor power",
"success": true
}